SHANDONG HUAYUAN BOILER · EST. 1968
[email protected]WhatsApp +86 158 6486 1976

HUAYUAN / PROJECT REFERENCE

Installation site of circulating fluidized bed coal-fired coal slurry boiler

The boiler is a single-tube horizontal type, forced circulation water pipe circulating fluidized bed boiler, which adopts a single furnace, forced circulation

The boiler is a single-tube horizontal type, forced circulation water pipe circulating fluidized bed boiler, which adopts a single furnace, forced circulation, suspension structure, and all steel frame π-type layout. The boiler is open above the operating floor, closed below the operating floor, and a concrete platform is set at the 8m elevation of the operating floor and 5.2m of the operating floor. The furnace adopts membrane water-cooled wall suspension structure, two high-temperature adiabatic cyclones are arranged at the furnace outlet, two-stage economizers are arranged in the tail shaft flue, and SCR denitrification installation positions are reserved between the two-stage economizers. Three sets of air preheaters for primary and secondary air are arranged below the economizer.

This boiler adopts advanced circulating fluidized bed combustion technology of Institute of Engineering Thermophysics, Chinese Academy of Sciences. This hot water boiler is used for large-scale centralized heating. The 4 sets of 70MW boilers in this project are mainly used for the heating project of the people's livelihood in Dongying District, Dongying City, which belongs to the large-scale heating project sponsored by Shandong Provincial Supervision and Dongying City.

1. Main design parameters

Rated thermal power   70MW

Rated water temperature 130 ℃

Rated outlet pressure (gauge pressure) 1.6 MPa

Rated return water temperature   70 ℃

Rated circulating water volume 1002t/h

Boiler exhaust temperature 132 ℃

Cold air temperature 20 ℃

Boiler design thermal efficiency 91.7%

Fuel consumption 16858kg/h

Primary hot air temperature   150 ℃

Secondary hot air temperature 150 ℃

First and second air volume ratio 50:50

Cycle magnification   30

Desulfurization efficiency (when the molar ratio of calcium to sulfur is 3) ≥ 93%